Home Products12KV Vacuum Circuit Breaker

Outdoor 12KV Vacuum Circuit Breaker

Good quality Outdoor Vacuum Circuit Breaker for sales
Good quality Outdoor Vacuum Circuit Breaker for sales
I'm Online Chat Now

Outdoor 12KV Vacuum Circuit Breaker

China Outdoor 12KV Vacuum Circuit Breaker supplier
Outdoor 12KV Vacuum Circuit Breaker supplier Outdoor 12KV Vacuum Circuit Breaker supplier Outdoor 12KV Vacuum Circuit Breaker supplier

Large Image :  Outdoor 12KV Vacuum Circuit Breaker

Product Details:

Place of Origin: XIAN CHINA
Brand Name: ERFA
Certification: ISO9001¬2000, CE, CCC
Model Number: ZW32-12

Payment & Shipping Terms:

Minimum Order Quantity: 1 unit
Price: Negotiated
Packaging Details: each piece in a wooden box with pallet
Delivery Time: 10 days after payment
Payment Terms: T/T
Supply Ability: 10000pcs per month
Contact Now
Detailed Product Description
Breaking Capacity:: High Voltage Circuit Breakers Rated Current: 630A
Poles Number: 3 Rated Voltage: 12kv
Rated Frequency: 50/60Hz
High Light:

outdoor vacuum circuit breaker

,

hv vacuum circuit breaker

ZW32-12 Type Outdoor HV Vacuum Circuit Breaker


General Description
ZW32-12 type outdoor high voltage vacuum circuit breaker is three-phase AC,50(60) Hz outdoor power distribution equipment with the rated voltage of 12kV.It is mainly used to break and close the load current,and short circuit current in the electric power system.It fits to be used to protect and control the circuit in substation,mining and industrial enterprises.It also can be used in the frequently operation places such as the rural power network. The product is accordance with GB1984-2003 standard.
The ZW32-12G VCB -Isolating switch combination consists of Vacuum circuit breaker body and isolating switch.
Applying ambient conditions
1. Ambient temperature:-30ºC~+40ºC.
2. The height above sea level:≤1000m(besides the special requirements).
3. Relative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.
4. Saturated vapor pressure:the average pressure of a day should be no more than 2.2kPa:the average pressure of a month should be no more than 1.8kPa.
5. Earthquake intensity:not exceed 8 degrees.
6. Wind pressure should be no more than 700pa(it is equivalent to wind sped of 34m/s).
7. The air filthy should be within III degree.
8. It should be installed in the places without fire,explosion,serious filth, chemical erosion and violent vibration.

Outdoor 12KV Vacuum Circuit BreakerOutdoor 12KV Vacuum Circuit BreakerOutdoor 12KV Vacuum Circuit Breaker